    V-Bank Dry Cooler Air Condenser for data center office building

    Ask Lasest Price
    Brand Name : ADV
    Model Number : ADV -UC-01
    Certification : ISO9001:2008
    Price : FOB SHANGHAI
    Supply Ability : 1~50 + Units + 25 Working Days
    Delivery Time : 7~15 Working Days
    • Product Details
    • Company Profile

    V-Bank Dry Cooler Air Condenser for data center office building

    V-Bank Dry Cooler Air Condenser for data center office building​

    Dry coolers can play a significant role in helping a building operate more efficiently. Though this equipment is not known for conserving energy, it can be utilized as a condensing unit for a heat recovery chiller. The primary function of a heat recovery chiller is to provide heating or chilled water from energy that is normally wasted, but it can also provide chilled water to supplement a building’s primary chilled water system in the event of a shut down or failure. When a heat recovery chiller supplements a chilled water system, there must be a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower. In certain applications, this type of design can eliminate the need for water or air cooled chillers to be connected to the building’s back up power supply, which can potentially reduce the size of an emergency generator.

    Application

    • Data centers
    • Office buildings
    • Hospitals/medical office buildings
    • Industrial/process systems
    • Heat transfer/recuperation
    • Power generation
    • Induction cooling

    Quality Details

    V-Bank Dry Cooler Air Condenser for data center office building

    V-Bank Dry Cooler Air Condenser for data center office building
    V-Bank Dry Cooler Air Condenser for data center office building

    Selection Data

    630/800 V-Bank Air-Cooler Condenser selection data(2.11mm Fin Spacing)
    Model Capacity Exchange surface Tube volume Air flow Sound Pressure Level Fan Data No. of fans Connection Weight
    kW*1 L m3/h dB(A)10m 3~400/50 mm mm kg
    W A N*D Inlet Outlet
    HCVS163-0062 62 142 23.3 18281 61 1600 3.2 1*630 2*34.9 2*22.23 300
    HCVS163-0067 67 189 31.1 17779 61 1600 3.2 1*630 2*34.9 2*22.23 325
    HCVS263-0127 126 284 46.6 36539 62 3200 6.4 2*630 2*34.9 2*22.23 455
    HCVS263-0140 140 378 62.1 35505 62 3200 6.4 2*630 2*34.9 2*22.23 502
    HCVS363-0187 187 425 69.9 54841 63 4800 9.6 3*630 2*41.3 2*28.6 610
    HCVS363-0207 207 567 93.2 53290 63 4800 9.6 3*630 2*41.3 2*28.6 679
    HCVS463-0253 253 567 93.2 73079 64 6400 12.8 4*630 2*41.3 2*28.6 729
    HCVS463-0280 280 756 124.3 71010 64 6400 12.8 4*630 2*41.3 2*28.6 820
    HCVS563-0315 315 709 116.5 91376 65 8000 16.0 5*630 2*54 2*35 860
    HCVS563-0353 353 945 155.3 88735 65 8000 16.0 5*630 2*54 2*35 980
    HCVD463-0218 218 434 69.9 70363 64 6400 12.8 4*630 2*41.3 2*28.6 533
    HCVD463-0250 250 578 93.2 67346 64 6400 12.8 4*630 2*41.3 2*28.6 641
    HCVD663-0338 338 651 104.8 105416 66 9600 19.2 6*630 2*54 2*35 765
    HCVD663-0375 375 868 139.8 101019 66 9600 19.2 6*630 2*54 2*35 873
    HCVD863-0451 451 868 139.8 140554 67 12800 25.6 8*630 2*54 2*35 1025
    HCVD863-0500 500 1157 186.4 134692 67 12800 25.6 8*630 2*67 2*41.3 1133
    HCVD1063-0561 561 1084 174.7 175747 68 16000 32.0 10*630 2*67 2*41.3 1275
    HCVD1063-0633 633 1446 233.0 168365 68 16000 32.0 10*630 2*67 2*41.3 1385
    HCVD1263-0681 681 1301 209.7 210831 69 19200 38.4 12*630 2*67 2*41.3 1420
    HCVD1263-0750 750 1735 279.6 202038 69 19200 38.4 12*630 2*67 2*41.3 1636
    HCVD1463-0796 796 1518 244.6 245970 70 22400 44.8 14*630 2*76.3 2*54 1650
    HCVD1463-0883 883 2024 326.2 235711 70 22400 44.8 14*630 2*76.3 2*54 1883
    HCVD1663-0917 917 1735 279.6 281022 71 25600 51.2 16*630 2*76.3 2*54 1840
    HCVD1663-1016 1016 2313 372.8 269298 71 25600 51.2 16*630 2*76.3 2*54 2135
    HCVD1863-1022 1021 1952 314.5 316247 72 28800 57.6 18*630 2*76.3 2*54 2050
    HCVD1863-1149 1149 2603 419.4 302863 72 28800 57.6 18*630 2*76.3 2*54 2385
    HCVD2063-1282 1282 2892 466.0 336514.8 73 32000 64.0 20*630 2*89 2*54 2633
    HCVD480-0251 251 510 83.9 80279 54 7200 15.2 4*800 2*41.3 2*35 735
    HCVD480-0276 276 681 111.8 74879 54 7200 15.2 4*800 2*54 2*41.3 835
    HCVD680-0381 381 766 125.8 120418 56 10800 22.8 6*800 2*54 2*41.3 1135
    HCVD680-0413 413 1021 167.8 112318 56 10800 22.8 6*800 2*67 2*41.3 1225
    HCVD880-0411 411 1021 167.8 120430 58 14400 30.4 8*800 2*67 2*41.3 1617
    HCVD880-0552 552 1361 223.7 149758 58 14400 30.4 8*800 2*67 2*41.3 1753
    HCVD1080-0634 634 1276 209.7 200697 60 18000 38.0 10*800 2*76.3 2*54 1894
    HCVD1080-0693 693 1702 279.6 187197 60 18000 38.0 10*800 2*76.3 2*54 2042
    HCVD1280-0827 827 2042 335.5 224637 62 21600 45.6 12*800 2*76.3 2*54 2327
    HCVD1480-0954 954 2382 391.4 262076 64 25200 53.2 14*800 2*89 2*54 2741
    HCVD1680-1104 1104 2723 447.3 299516 66 28800 60.8 16*800 2*89 2*54 2947
    HCVD1880-1286 1286 3063 503.3 336576 66 32400 68.4 18*800 2*89 2*54 3342
    1. Capacity based on sub-cooling 0K,ambient temp of 35℃,condensing temp of 50℃,suctio temp of 100℃,R404A..
    2. The sound pressure level data are average tested at the intersection of fan plane and reflection plane 10meters from axis

    OEM Customation

    Frame

    Fin

    Heat-exchange Tube

    Fan

    Electric Control

    Other

    Hot dip galvanized steel

    Hydrophilic Fin

    Stainless steel 304

    EC Fan

    Junction Box

    HT/LT Double-Bank Heat-exchange

    Stainless steel 304

    Almg 25

    Stainless steel 316

    Explosion-proof fan motors

    safety Switch

    Adiabatic Water spraying system

    Stainless steel 316

    Copper Fin

    B10

    Marine Fan Motor

    Control Box

    Steel Structure and safe access for service

    Aluminum

    Pre-coated Epoxy Fin

    B30

    Stainless Steel Guards

    VFD Control Box

    Air filter

    Copper Tinned Fin

    Titanium

    Temperature/Pressure Control Box

    Heresite/ Blygold/Epxoy Coated Fin

    Advantages

    Design software Using the mature European design software, according to the EN1048 and actual demand accurate design of heat exchanger, can design the special low temperature cold agent etc.
    Heat exchange structure Supported to the casing by means of a "flating-bed " system that avoids any kind of contact between the heat-exchange tubes and the supporting end plates,assuring a long life for the heat-exchange without leaks. Heat-exchange sections separated and independent for each fan. The standard fin spacing is 2.1mm,Fin pitch up to 12mm for low air pressure drop.
    Condenser structure Shape with flexible and changeable,--Flat-bed,W-Bank,V-Bank; Fan direction--blowing and sucking. Finned length up to 12m,Finned height up to 2.7m.
    Heat Exchange Tube Using copper content more than 99.9% pipe,using three type copper tube 3/8",1/2",5/8" Increased the thermal efficiency and low fluid pressure drop .
    Casing Using galvanized sheet case, spraying outdoor powder coatings, and after high temperature curing, high strength of corrosion resistance is strong, the standard color for RAL9003.
    Fans Low noise axial fans,with maintenance free motors in protection class IP 54,Internal motor protection with thermo contacts.With precise design, forming mould processing, air volume is larger and more efficient.

    Project Experience
    • 3D model drawing available
    • Prototype testing and confirmation
    • Steel frame support, Front to Back type design and manufacturing
    • Easy mounting and maintain, Good anti-vibration
    • Stable Performance & Low Pressure Drop
    • Compact Design & Light Weight
    • Motor & Fan is Optional
    • 12 Month Global Warranty
    • OEM Production is Offered

    Purchasing Guide

    You just need to tell us your specific requirements and environmental parameters so that we can make professional quotations accordingly.

    Please advise:

    Oil parameter Fluid
    Flow
    Inlet temperature (℃)
    Cooling power (kw)
    Max. allowable pressure drop
    Max. work pressure (MPa)
    Air parameter Flow
    Inlet temperature (℃)
    Cooling power (kw)
    Max. allowable pressure drop
    Max. work pressure (MPa)
    Cool air parameter Flow & Pressure curve
    Inlet temperature (℃)
    Air trace
    Mounting Max overall dimension
    Location of connections
    Requirement of structure
    Working condition

    Be free to contact us if you need any further information, thank you!